Description:
- PVC compound for different insulation and sheaths in electrical and communication cables for temprature range of 70 - 90°C of conductor temperature acc. as IEC 60502, IEC 60227 , IEC 60189 and TCI.
- PVC granules are available in natural or coloured.
- PVC types: A, C, D, E, ST1, ST2, ST4, ST5, KHF, KHTI and KHTS
Application of PVC granule type A, C, D, E:
E |
D |
C |
A |
PVC granule type |
Cable Insulation with Max resistance with 90°C |
Insulation for non-flexible wires below and including 450/750 V |
Insulation for flexible wires below and including 450/750 V |
Sheath for 0.6/1 KV cables |
Application |
Technical data for OVC granule type A, C, D, E:
Type of PVC |
Technical data |
|||||||
E |
D |
C |
A |
Unit |
Item |
No |
|
|
15 |
10 |
12.5 |
12.5 |
N/mm2 |
Tensile strength |
Mechanical properties without ageing |
1-1 |
Non electrical |
150 | 150 | 125 | 150 | % | elongation | |||
15 | 10 | 12.5 | 12.5 | N/mm2 | tensile strength | Mechanical properties after ageing | 1-2 | |
±25 | ±20 | ±20 | ±25 | % | variation with samples before ageing | |||
150 | 150 | 125 | 150 | % | elongation | |||
±25 | ±20 | ±20 | ±25 | % | variation with samples before ageing | |||
1.4 | 1.5 | 1.5 | 1.48 | gr/cm3 | Density | 1-3 | ||
2 | 2 | 2 | - | mg/cm2 | during 7 days | Loss of mass | 1-4 | |
115°C-10days |
80°C | 80°C | °C | in temperature | ||||
78 | 72 | 78 | 84 | Shore A | Hardness | 1-5 | ||
1010 | 1010 | 1010 | 1010 | Ω.cm | Volume resistivity at 70°C | 2 |
Electrical |
|
90 | 70 | 70 | 70 | °C | Permanent working temperature | 3-1 |
Thermic |
|
160 | 150 | 145 | 150 | °C | Melt temperature | 3-2 |
PVC granule type Application ST1, ST2, ST4, ST5:
ST5 |
ST4 |
ST2 |
ST1 |
PVC granule type |
Sheath for fixed installation cables below and including 450/750 V |
Sheath for flexible cables below and including 450/750 V |
Sheath cable of 0.6/1 KV with temparature 90°C |
Sheath cable of 0.6/1 KV |
Application |
Technical data/ PVC granule type ST1, ST2, ST4, ST5:
PVC granule type |
Technical data |
|||||||
ST5 |
ST4 |
ST2 |
ST1 |
Unit |
Item |
No |
|
|
10 | 12.5 | 12.5 | 12.5 |
N/mm2 |
tensil strength |
Mechanical properties without ageing |
1-1 |
Non electrical |
150 | 125 | 150 | 150 | % | elongation | |||
12.5 | 12.5 | 12.5 | 12.5 | N/mm2 | tensile strength | Mechanical properties after ageing | 1-2 | |
±20 | ±20 | ±25 | ±25 | % | variation with samples before ageing | |||
125 | 125 | 150 | 150 | % | elongation | |||
±20 | ±20 | ±25 | ±25 | % | variation with samples before ageing | |||
1.45 | 1.48 | 1.54 | 1.54 | gr/cm3 | Density | 1-3 | ||
2 | 2 | 1.5 | - | mg/cm2 | during 7 days | Loss of mass | 1-4 | |
- | - | - | °C | in temperature | ||||
72 | 80 | 82 | 82 | Shore A | Hardness | 1-5 | ||
- | - | - | - | Ω.cm | Volume resistivity at 70°C | 2 |
Electrical |
|
70 | 70 | 90 | 80 | °C | 3-1 |
Thermic |
||
145 | 150 | 160 | 160 | °C | Melt temperature | 3-2 |
Application of type of PVC granule KHF, KHTI, KHTS:
KHTS |
KHTI |
KHF |
Type of PVC granule |
Sheath Telecommunication cable |
Insulation Telecommunication cable |
Filler materials for Multi cables |
Application |
Technical data for PVC type KHF, KHTI, KHTS:
PVC granule type |
Technical data |
||||||
KHTS |
KHTI |
KHF |
Unit |
Item |
No |
|
|
12.5 | 15 | 10 |
N/mm2 |
tensile strength |
Mechanical properties without ageing |
1-1 |
Non electrical |
150 | 150 | 150 | % | elongation | |||
12.5 | 15 | - | N/mm2 | tensile strength | Mechanical properties after ageing | 1-2 | |
±20 | ±20 | - | % | variation with samples before ageing | |||
150 | 150 | - | % | elongation | |||
±20 | ±20 | - | % | variation with samples before ageing | |||
1.5 | 1.4 | 1.65 | gr/cm3 | Density | 1-3 | ||
- | - | - | mg/cm2 | during 7 days | Loss of mass | 1-4 | |
°C | in temperature | ||||||
70 | 82 | 60 | Shore A | Hardness | 1-5 | ||
- | - | - | Ω.cm | Volume resistivity at 70°C | 2 |
Electrical |
|
50 | 50 | 70 | °C | Permanent working temperature | 3-1 |
Thermic |
|
160 | 155 | 150 | °C | Melt temperature | 3-2 |