Flexible control cable NYSLY 300/500 V

 

Technical data:

- Control cable according to IEC 60227-7 , DIN VDE 0245

- Temperature range:

max. permissible temperature in conductor

   in operation : C°+70

  in short-circuit: C°+150

  flexing : C°-5 to C°+50

  fixed installation : C°-40 to C°+70

- Nominal voltage: U0/U=300/500 V

-Test voltage a.c. ,50 Hz: 2 KV, 5min

Cable structure:

- Cu / PVC / PVC

- Copper conductor class 5 IEC 60228

- Insulation PVC/D

- Cores stranded in layer without central core

- Sheath  PVC/ST9 70°C

Application:

Used as control and connecting cable in machines ,conveyor belts ,production lines ,machine tool industries ,progressive assembly lines ,automatic handling apparatus for medium mechanical stress.

Cross section with 0.5:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

45 9.0 39 5.7 0.7 0.6 2*0.5
53 9.0 39 6.0 0.7 0.6 3*0.5
66 9.0 39 6.8 0.8 0.6 4*0.5
78 6.7 39 7.4 0.8 0.6 5*0.5
100 6.7 39 8.2 0.9 0.6 6*0.5
120 5.8 39 8.2 0.9 0.6 7*0.5
125 5.8 39 9.1 1.0 0.6 8*0.5
166 5.0 39 10.6 1.0 0.6 10*0.5
186 4.8 39 11.1 1.1 0.6 12*0.5
264 4.0 39 13.1 1.2 0.6 18*0.5
294 4.0 39 13.1 1.2 0.6 19*0.5
366 3.6 39 15.4 1.3 0.6 25*0.5
393 3.5 39 16.0 1.4 0.6 27*0.5
510 3.3 39 18.0 1.5 0.6 36*0.5
520 3.3 39 18.0 1.5 0.6 37*0.5
556 3.1 39 18.9 1.6 0.6 40*0.5
608 3.1 39 19.5 1.6 0.6 42*0.5
710 3.0 39 21.5 1.7 0.6 50*0.5
826 3.0 39 22.9 1.8 0.6 61*0.5

Cross section with 0.75:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

57 12.0 26 6.4 0.8 0.6 2*0.75
68 12.0 26 6.7 0.8 0.6 3*0.75
81 12.0 26 7.3 0.8 0.6 4*0.75
109 9.0 26 8.2 0.6 0.6 5*0.75
130 9.0 26 8.9 0.6 0.6 6*0.75
143 8.0 26 9.1 1.0 0.6 7*0.75
165 7.2 26 9.8 1.0 0.6 8*0.75
215 6.6 26 11.7 1.1 0.6 10*0.75
231 6.3 26 12.0 1.1 0.6 12*0.75
336 6.0 26 14.5 1.3 0.6 18*0.75
342 5.4 26 14.5 1.3 0.6 19*0.75
466 4.8 26 17.0 1.4 0.6 25*0.75
512 4.8 26 17.6 1.5 0.6 27*0.75
665 4.2 26 19.7 1.6 0.6 36*0.75
680 4.2 26 19.7 1.6 0.6 37*0.75
706 4.2 26 20.7 1.7 0.6 40*0.75
762 4.0 26 21.6 1.8 0.6 42*0.75
900 4.0 26 23.5 1.8 0.6 50*0.75
1062 4.0 26 25.2 2.0 0.6 61*0.75

Cross section with 1.0:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

66 15.0 19.5 6.7 0.8 0.6 2*1
79 15.0 19.5 7.1 0.8 0.6 3*1
103 15.0 19.5 7.7 0.8 0.6 4*1
121 11.2 19.5 8.6 0.9 0.6 5*1
150 11.2 19.5 9.6 1.0 0.6 6*1
180 9.7 19.5 9.6 1.0 0.6 7*1
206 9.7 19.5 10.6 1.1 0.6 8*1
243 8.3 19.5 12.5 1.2 0.6 10*1
278 8.0 19.5 12.9 1.2 0.6 12*1
397 6.7 19.5 15.3 1.3 0.6 18*1
442 6.7 19.5 15.3 1.3 0.6 19*1
552 6.0 19.5 18.0 1.4 0.6 25*1
590 5.8 19.5 18.6 1.5 0.6 27*1
772 5.5 19.5 21.1 1.7 0.6 36*1
800 5.5 19.5 21.1 1.7 0.6 37*1
850 5.2 19.5 22.0 1.8 0.6 40*1
905 5.2 19.5 23.0 1.8 0.6 42*1
1082 5.0 19.5 25.1 1.9 0.6 50*1
1275 5.0 19.5 27.0 2.1 0.6 61*1

Cross section with 1.5:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

88 18.0 13.3 7.7 0.8 0.7 2*1.5
111 18.0 13.3 8.3 0.9 0.7 3*1.5
135 18.0 13.3 9.1 0.9 0.7 4*1.5
165 13.5 13.3 10.1 1.0 0.7 5*1.5
209 13.5 13.3 11.3 1.1 0.7 6*1.5
225 12.0 13.3 11.5 1.2 0.7 7*1.5
261 10.8 13.3 12.5 1.2 0.7 8*1.5
353 9.9 13.3 14.7 1.3 0.7 10*1.5
390 9.5 13.3 15.1 1.3 0.7 12*1.5
565 90 13.3 18.0 1.5 0.7 18*1.5
575 8.1 13.3 18.0 1.5 0.7 19*1.5
795 7.2 13.3 21.5 1.7 0.7 25*1.5
847 7.2 13.3 22.1 1.8 0.7 27*1.5
1105 6.3 13.3 25.1 2.0 0.7 36*1.5
1115 6.3 13.3 25.1 2.0 0.7 37*1.5
1212 6.3 13.3 26.2 2.1 0.7 40*1.5
1290 6.0 13.3 27.2 2.1 0.7 42*1.5
1545 6.0 13.3 30.0 2.2 0.7 50*1.5
1815 6.0 13.3 32.0 2.4 0.7 61*1.5

end faq