Flexible control cable ( N ) YMHY 300/500 V

 

Technical data:

- Control cable similar to IEC 60227-7 , DIN VDE 0245

- Temperature range:

max. permissible temperature in conductor

   in operation : C°+70

  in short-circuit : C°+150

   flexing : C°-5 to C°+50

   fixed installation : C°-40 to C°+70

- Nominal voltage: U0/U=300/500 V

- Test voltage a.c. ,50 Hz: 2 KV, 5min

Cable structure:

- Cu / PVC / PVC

- Copper conductor class 5 IEC 60228

- Insulation PVC/D

- Cores stranded in layer without central core

- Sheath  PVC/ST9 70°C

Application:

Used as control and connecting cable in machines ,conveyor belts ,production lines ,machine tool industries ,progressive assembly lines ,automatic handling apparatus for medium mechanical stress.

Cross section with 4:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

197 34 4.95 11.0 1.3 0.8 2*4
240 34 4.95 11.7 1.3 0.8 3*4
300 34

4.95

13.0 1.4 0.8 4*4
360 25.5 4.95 14.2 1.4 0.8 5*4
480 22.1 4.95 15.5 1.4 0.8 7*4
830 17.85 4.95 21.0 1.6 0.8 12*4

Cross section with 6:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

281 43 3.3 12.2 1.3 0.8 2*6
360 43 3.3 13.1 1.4 0.8 3*6
420 43 3.3 14.5 1.4 0.8 4*6
520 32.25 3.3 16.0 1.5 0.8 5*6
645 27.95 3.3 18.0 1.5 0.8 7*6

Cross section with 10:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

400 59 1.91 15.8 1.5 1.0 2*10
532 59 1.91 16.3 1.5 1.0 3*10
693 59 1.91 18.0 1.5 1.0 4*10
860 44.25 1.91 20.0 1.6 1.0 5*10
1110 38.35 1.91 22.0 1.6 1.0 7*10

Cross section with 16:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

600 79 1.21 20.0 1.6 1.0 2*16
810 79 1.21 20.5 1.6 1.0 3*16
1020 79 1.21 22.5 1.7 1.0 4*16
1250 59.25 1.21 25.0 1.7 1.0 5*16
1770 51.35 1.21 28.0 1.8 1.0 7*16

Cross section with 25:

Approx. Current

kg/km

Current capacity in air C°30

(A)

Max. resistance at C°20

(Ω/KM)

Overall dimensions

mm

Sheath thickness

mm

Insulation thickness

mm

No.cores xNominal cross section

mm2

730 106 0.78 22.5 1.8 1.2 2*25
1210 106 0.78 24.0 1.8 1.2 3*25
1560 106 0.78 27.2 1.8 1.2 4*25
1850 79.5 0.78 30.5 1.9 1.2 5*25

end faq