Technical data:
- Telephone cable acc. to TCI , VDE 0815 , IEC 60189
- Temperature range:
during installation C°-5 to C°+50
before and after installation C°-30 to C°+70
- Nominal voltage: Max 200V
- Voltage test:
core/core 2000V a.c. 50Hz
core/screen 1000V a.c. 50Hz
- Insulation resistance: Min 500Mohm*km
- Mutual capacitance at: 100nF/Km at 1000Hz
Cable structure:
- Bare or tinned annealed copper conductor, solid, 0.4,0.5,0.6,0.8 mm
- PVC insulation
- Twinning: two insulated conductor twisted together.
- static screen: polyester tape+drain wire+AL.polyester tape
- PVC sheath
Application:
These cables are used for telephone and signal transmission for permanent laying on or under plaster, outdoor on walls, and in Main Distribution Frame ( MDF ) systems.
Laying underground is not permissible.
Conductor diameter 0.4:
Approx. weight kg/km |
Overall diameter mm |
Sheath thickness mm |
Insulation thickness mm |
Conductor diameter mm |
Number of pairs
|
26 | 4.5 | 0.8 | 0.2 | 0.4 | 2 |
36 | 5.5 | 0.8 | 0.2 | 0.4 | 4 |
52 | 6.5 | 1.0 | 0.2 | 0.4 | 6 |
60 | 7.0 | 1.0 | 0.2 | 0.4 | 8 |
70 | 7.5 | 1.0 | 0.2 | 0.4 | 10 |
95 | 9.0 | 1.0 | 0.2 | 0.4 | 15 |
118 | 10.0 | 1.0 | 0.2 | 0.4 | 20 |
140 | 11.0 | 1.0 | 0.2 | 0.4 | 25 |
170 | 12.0 | 1.2 | 0.2 | 0.4 | 30 |
220 | 13.2 | 1.2 | 0.2 | 0.4 | 40 |
260 | 14.5 | 1.2 | 0.2 | 0.4 | 50 |
300 | 15.5 | 1.2 | 0.2 | 0.4 | 60 |
390 | 17.5 | 1.2 | 0.2 | 0.4 | 80 |
470 | 19.5 | 1.2 | 0.2 | 0.4 | 100 |
690 | 23.0 | 1.4 | 0.2 | 0.4 | 150 |
900 | 27.0 | 1.6 | 0.2 | 0.4 | 200 |
Conductor diameter 0.5:
Approx. weight kg/km |
Overall diameter mm |
Sheath thickness mm |
Insulation thickness mm |
Conductor diameter mm |
Number of pairs
|
32 | 4.9 | 0.8 | 0.25 | 0.5 | 2 |
47 | 6.1 | 0.8 | 0.25 | 0.5 | 4 |
66 | 7.2 | 1.0 | 0.25 | 0.5 | 6 |
81 | 8.0 | 1.0 | 0.25 | 0.5 | 8 |
95 | 8.6 | 1.0 | 0.25 | 0.5 | 10 |
128 | 10.0 | 1.0 | 0.25 | 0.5 | 15 |
160 | 11.0 | 1.0 | 0.25 | 0.5 | 20 |
205 | 12.5 | 1.2 | 0.25 | 0.5 | 25 |
236 | 13.5 | 1.2 | 0.25 | 0.5 | 30 |
300 | 15.0 | 1.2 | 0.25 | 0.5 | 40 |
360 | 16.5 | 1.2 | 0.25 | 0.5 | 50 |
438 | 18.0 | 1.4 | 0.25 | 0.5 | 60 |
560 | 20.5 | 1.4 | 0.25 | 0.5 | 80 |
690 | 22.5 | 1.4 | 0.25 | 0.5 | 100 |
1100 | 27.0 | 1.6 | 0.25 | 0.5 | 150 |
1450 | 31.5 | 1.8 | 0.25 | 0.5 | 200 |
Conductor diameter 0.6:
Approx. weight kg/km |
Overall diameter mm |
Sheath thickness mm |
Insulation thickness mm |
Conductor diameter mm |
Number of pairs
|
41 | 5.6 | 1.0 | 0.25 | 0.6 | 2 |
65 | 7.0 | 1.0 | 0.25 | 0.6 | 4 |
85 | 8.0 | 1.0 | 0.25 | 0.6 | 6 |
105 | 9.0 | 1.0 | 0.25 | 0.6 | 8 |
120 | 9.7 | 1.0 | 0.25 | 0.6 | 10 |
169 | 11.1 | 1.0 | 0.25 | 0.6 | 15 |
210 | 12.5 | 1.0 | 0.25 | 0.6 | 20 |
270 | 14.0 | 1.2 | 0.25 | 0.6 | 25 |
305 | 15.0 | 1.2 | 0.25 | 0.6 | 30 |
390 | 16.7 | 1.2 | 0.25 | 0.6 | 40 |
472 | 18.2 | 1.2 | 0.25 | 0.6 | 50 |
540 | 20.0 | 1.4 | 0.25 | 0.6 | 60 |
730 | 22.6 | 1.4 | 0.25 | 0.6 | 80 |
895 | 25.0 | 1.4 | 0.25 | 0.6 | 100 |
1310 | 30.0 | 1.6 | 0.25 | 0.6 | 150 |
1740 | 35.0 | 1.8 | 0.25 | 0.6 | 200 |
Conductor diameter 0.8:
Approx. weight kg/km |
Overall diameter mm |
Sheath thickness mm |
Insulation thickness mm |
Conductor diameter mm |
Number of pairs
|
59 | 6.5 | 1.0 | 0.3 | 0.8 | 2 |
90 | 8.0 | 1.0 | 0.3 | 0.8 | 4 |
122 | 9.5 | 1.0 | 0.3 | 0.8 | 6 |
152 | 10.5 | 1.0 | 0.3 | 0.8 | 8 |
182 | 11.2 | 1.0 | 0.3 | 0.8 | 10 |
260 | 13.5 | 1.2 | 0.3 | 0.8 | 15 |
335 | 15.0 | 1.2 | 0.3 | 0.8 | 20 |
420 | 17.0 | 1.4 | 0.3 | 0.8 | 25 |
500 | 18.2 | 1.4 | 0.3 | 0.8 | 30 |
640 | 20.5 | 1.4 | 0.3 | 0.8 | 40 |
796 | 23.0 | 1.6 | 0.3 | 0.8 | 50 |
930 | 25.0 | 1.6 | 0.3 | 0.8 | 60 |
1250 | 28.5 | 1.8 | 0.3 | 0.8 | 80 |
1550 | 32.0 | 1.8 | 0.3 | 0.8 | 100 |