Telephone cable for building and internal usage J-Y(st)Y

 

Technical data:

- Telephone cable acc. to TCI , VDE 0815 , IEC 60189

- Temperature range:

   during installation C°-5 to C°+50

   before and after installation C°-30 to C°+70

- Nominal voltage: Max 200V

- Voltage test:

   core/core     2000V a.c. 50Hz

   core/screen     1000V a.c. 50Hz

- Insulation resistance: Min 500Mohm*km

- Mutual capacitance at: 100nF/Km at 1000Hz

Cable structure:

- Bare or tinned annealed copper conductor, solid, 0.4,0.5,0.6,0.8 mm

- PVC insulation

- Twinning: two insulated conductor twisted together.

- static screen: polyester tape+drain wire+AL.polyester tape

- PVC sheath

Application:

These cables are used for telephone and signal transmission for permanent laying on or under plaster, outdoor on walls, and in Main Distribution Frame ( MDF ) systems.

Laying underground is not permissible.

Conductor diameter 0.4:

Approx. weight

kg/km

Overall diameter

mm

Sheath thickness

mm

Insulation thickness

mm

Conductor diameter

mm

Number of pairs

 

26 4.5 0.8 0.2 0.4 2
36 5.5 0.8 0.2 0.4 4
52 6.5 1.0 0.2 0.4 6
60 7.0 1.0 0.2 0.4 8
70 7.5 1.0 0.2 0.4 10
95 9.0 1.0 0.2 0.4 15
118 10.0 1.0 0.2 0.4 20
140 11.0 1.0 0.2 0.4 25
170 12.0 1.2 0.2 0.4 30
220 13.2 1.2 0.2 0.4 40
260 14.5 1.2 0.2 0.4 50
300 15.5 1.2 0.2 0.4 60
390 17.5 1.2 0.2 0.4 80
470 19.5 1.2 0.2 0.4 100
690 23.0 1.4 0.2 0.4 150
900 27.0 1.6 0.2 0.4 200

Conductor diameter 0.5:

Approx. weight

kg/km

Overall diameter

mm

Sheath thickness

mm

Insulation thickness

mm

Conductor diameter

mm

Number of pairs

 

32 4.9 0.8 0.25 0.5 2
47 6.1 0.8 0.25 0.5 4
66 7.2 1.0 0.25 0.5 6
81 8.0 1.0 0.25 0.5 8
95 8.6 1.0 0.25 0.5 10
128 10.0 1.0 0.25 0.5 15
160 11.0 1.0 0.25 0.5 20
205 12.5 1.2 0.25 0.5 25
236 13.5 1.2 0.25 0.5 30
300 15.0 1.2 0.25 0.5 40
360 16.5 1.2 0.25 0.5 50
438 18.0 1.4 0.25 0.5 60
560 20.5 1.4 0.25 0.5 80
690 22.5 1.4 0.25 0.5 100
1100 27.0 1.6 0.25 0.5 150
1450 31.5 1.8 0.25 0.5 200

Conductor diameter 0.6:

Approx. weight

kg/km

Overall diameter

mm

Sheath thickness

mm

Insulation thickness

mm

Conductor diameter

mm

Number of pairs

 

41 5.6 1.0 0.25 0.6 2
65 7.0 1.0 0.25 0.6 4
85 8.0 1.0 0.25 0.6 6
105 9.0 1.0 0.25 0.6 8
120 9.7 1.0 0.25 0.6 10
169 11.1 1.0 0.25 0.6 15
210 12.5 1.0 0.25 0.6 20
270 14.0 1.2 0.25 0.6 25
305 15.0 1.2 0.25 0.6 30
390 16.7 1.2 0.25 0.6 40
472 18.2 1.2 0.25 0.6 50
540 20.0 1.4 0.25 0.6 60
730 22.6 1.4 0.25 0.6 80
895 25.0 1.4 0.25 0.6 100
1310 30.0 1.6 0.25 0.6 150
1740 35.0 1.8 0.25 0.6 200

Conductor diameter 0.8:

Approx. weight

kg/km

Overall diameter

mm

Sheath thickness

mm

Insulation thickness

mm

Conductor diameter

mm

Number of pairs

 

59 6.5 1.0 0.3 0.8 2
90 8.0 1.0 0.3 0.8 4
122 9.5 1.0 0.3 0.8 6
152 10.5 1.0 0.3 0.8 8
182 11.2 1.0 0.3 0.8 10
260 13.5 1.2 0.3 0.8 15
335 15.0 1.2 0.3 0.8 20
420 17.0 1.4 0.3 0.8 25
500 18.2 1.4 0.3 0.8 30
640 20.5 1.4 0.3 0.8 40
796 23.0 1.6 0.3 0.8 50
930 25.0 1.6 0.3 0.8 60
1250 28.5 1.8 0.3 0.8 80
1550 32.0 1.8 0.3 0.8 100

end faq